1 / 6

Low Speed Room Temperature Centrifuge M3050

Kuantitas
Stok : Sisa 9999

Technical Parameters:

Model

M3050 (room temperature)

Max. speed

4000rpm

Speed accuracy

±10rpm/min

Max. relative centrifugal force

3437xg

Machine noise

≤60dB(A)

Max. capacity

8×15ml+4×50ml

net weight

25KG

Timing range

1s—99min59s

Size (length x width x height)

460×400×270mm)

Support power supply

AC 220±22V 50Hz 10A

Drive motor

DC brushless motor

Power

500W

 

 

Rotor parameters:

 

Angle rotor #1

capacity:12×10ml

(Optional 2ml test tube pad)

max. speed: 4000rpm

max. relative centrifugal force: 1880xg

 

Angle rotor#2

capacity:8×15ml

max. speed: 4000rpm

max. relative centrifugal force: 1880xg

Angle rotor #3

capacity:12×10/15ml

max. speed: 4000rpm

max. relative centrifugal force: 2250xg

Angle rotor #4

capacity:24×10ml

max. speed: 4000rpm

max. relative centrifugal force: 2250xg

Angle rotor #5

capacity:6×50ml

max. speed: 4000rpm

max. relative centrifugal force: 2250xg

Horizontal disk rotor #6

capacity:8×10/15ml

max. speed: 4000rpm

max. relative centrifugal force: 2200xg

Horizontal disk rotor #7

capacity:8×15ml+4×50ml

max. speed: 4000rpm

max. relative centrifugal force: 2810xg

Horizontal disk rotor #8

capacity:24×5ml

max. speed: 4000rpm

max. relative centrifugal force: 2200xg

 

Function Introduction:

  • Stainless steel centrifugal chamber one-time drawing strength is high, wind resistance is small.
  • It has the functions of differential centrifugation, gradient centrifugation, point centrifugation and timed centrifugation.
  • The equilateral triangle method fixes the door cover to exert uniform force and is safer during the operation of the centrifuge.
  • There are overspeed, overtemperature, imbalance and door cover protection to protect personal safety and instrument safety.
  • The emergency opening port is equipped with a protective head on the side of the instrument, and there is no pull switch, which is convenient for opening the lid in an emergency and eliminates the safety risks caused by misoperation.
  • All centrifuge tubes ranging from 0.2ml to 50ml can be selected for centrifugation using a wide range of rotors and adapters.
  • The 5-inch touch screen operation is simple and convenient. The centrifugal force parameter can be set to 1xg, the speed can be set to 1rpm, and the time can be set to 1s. The large screen displays the parameters such as speed, centrifugal force, time, temperature, and addition and subtraction. Parameters can be changed during operation without stopping the machine.
  • Free worldwide shipping

  • Free returns

  • Carbon neutral

  • Secure payments

Your Trusted Partner in Centrifugation Solutions